ZETRON 2000 Series Specifikace Strana 144

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 376
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 143
Multiport for TNPP and TAP Outdial
144 025-9035AA
Port two received an inbound packet that had an inertia value of one, and the routing for
the destination indicated that the packet was to be routed out another serial port. This is
caused by an error in network programming. One possibility is that this terminal should
not be routing the destination, 0105 in the example, received from this port, port two in the
example, back out another port. Another other possibility is that the node originating the
page, which is 0002 in the example, does not have the inertia for the destination set high
enough.
- NET0002 packet too big 03:56:50p 1 7AL 2,0105N
Port two received an inbound packet that appeared to be too long, containing more than
1024 bytes. Generally, this is caused by noise or other problems on the link, or by
excessive traffic on a simplex or blind link.
- NET0002 packet bad CRC 03:57:12p 1 7AL 2,0105N
Port two received an inbound packet that failed the CRC error check. Generally, this is
caused by interference on the link. The constant appearance of this log message indicates
possible problems with the inter-node link, such as noise or low signal levels.
- NET0002 packet SUB-ETB 03:57:33p 1 7AL 2,0105N
Port two received an inbound packet that possibly had a non-standard control sequence.
The inter-block marker, the
<ETB> byte, appears to have arrived as an escaped character
pair,
<SUB>. Some TNPP implementations do this, and Zetron's TNPP can be
programmed to handle the condition. The other possibility is that the
<ETB> byte was
actually part of a page's message, however this is not very likely.
. NET0002 port unk node 03:59:02p 1 7AL 2,4444N
A network inbound packet was received at port 2, and the network card had not been
programmed to handle the destination node ID (“4444” in the example).
- 0099 test pg RS fail 09:59:15a 2 C TAP03D ID [ 16]
Sample of a failed ID page to a TAP outdial destination.
TNPP Link Tips - UDS 202T and Leased Line
When first connecting the modems, you will find it best to have an individual at each site
and in communication with each other. Verify that the modems are properly connected to
the telephone lines.
Note that in leased line, or 4-wire, mode the modem connection to the telephone line is
very similar to an RS-232 type connect in that there is a transmit pair of lines and a receive
pair. You must make sure that one modem has its transmit pair connected to the other
modem's receive pair.
First power the modems on and run their self-test by moving the front panel rotary switch
to the ST position. Verify that the TM LED is steadily on. If this LED is flashing, then the
modem is failing its internal tests.
Zobrazit stránku 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 375 376

Komentáře k této Příručce

Žádné komentáře